EtherCAT® accessories technical specifications

ECAT-SYNC-JUNCTION technical specifications

EtherCAT SYNC JUNCTION
Interface
Data interfaceEtherCAT®
Data Rate100 Mbps Full Duplex bus speed
Max. Throughput per ChainFrom 6 MB/s to 10 MB/s (see 1)
Sync Accuracy< 200 ns within same EtherCAT chain < 2 µs using sync for multiple EtherCAT chains below 1 sample to Sirius®
EtherCAT®Max. Cable Length 100 m
Max. Number of Units64 or more (power injectors may be required)
Data Interface ConnectionLEMO 1T EtherCAT® hybrid cable Single cable for data, power and sync, daisy chainable
Power specification
Power Supply9-48 V DC
Current8 A DC max
Power ConsumptionTyp. 1.3 W (Max. 1.5 W) (without additional power daisy-chain)
Environmental specification
Operating Temperature-40 to 70°C
Storage Temperature-40 to 85°C
Shock & VibrationShock: SIST EN 60068-2-27:2009 (100 g, 6 ms) Random vibration
1) It depends on the devices connected, numbers of channels, configuration, length of cables and other parameters.
Rev.: 1671516000

DS-HUBe7 technical specifications

DS-HUBe7
Interface
Data interfaceEtherCAT®
Data Rate100 Mbps Full Duplex bus speed
Max. Throughput per ChainFrom 6 MB/s to 10 MB/s (see 1)
Sync Accuracybelow 1 sample to Sirius®
EtherCAT®Max. Cable Length 100 m
Max. Number of Units64 or more (power injectors may be required)
Data Interface ConnectionLEMO 1T EtherCAT® hybrid cable Single cable for data, power and sync, daisy chainable
InputSingle IN port, L1T8m (data only)
Output7x OUT port, L1T8f (data and power from POWER IN)
Power
Power supply24 V typ. (18 - 30 V)
Maximum current10 A typ., 15 A max.
Power consumptionTyp. 4 W (excl. ECAT devices)
Power out
TypeLEMO 2pin female, daisy chain
Output VoltageEqual to input power supply voltage
EtherCAT® Power out
TypeSwitched input supply on EtherCAT® connector, LEMO 8pin female
Maximum current6 A typ.
Output VoltageEqual to input power supply voltage
Environmental
Operating Temperature-25 to 60 °C
Storage Temperature-40 to 85 °C
Humidity5 to 95 % RH non-condensing at 50 °C
IP ratingIP50
Shock & VibrationVibration sweep sinus (EN 60068-2-6:2008) Vibration random (EN 60721-3-2: 1997 - Class 2M2) Shock (EN 60068-2-27:2009) MIL-STD-810D
Physical
Dimensions266 x 139 x 65 mm
Weight1.2 kg
1) It depends on the devices connected, numbers of channels, configuration, length of cables and other parameters.
Rev: 1615809600

ECAT-REPEATER technical specifications

Interface
Data interfaceEtherCAT®
Data Rate100 Mbps Full Duplex bus speed
Max. Throughput per ChainFrom 6 MB/s to 10 MB/s (see 1)
Sync Accuracybelow 1 sample to Sirius®
EtherCAT®Max. Cable Length 50 m
Data Interface ConnectionLEMO 1T EtherCAT® hybrid cable Single cable for data, power and sync, daisy chainable
Input connectorL1T8m (data, power and sync)
Output connectorL1T8f (data, power and sync)
Power
Power supply9 - 48 VDC
Maximum currentmax. 7.5 A
Power consumptionTyp. 0.72 W, Max. 1 W
Environmental
Operating Temperature-40 to 85 °C
Storage Temperature-40 to 85 °C
Humidity5 to 95 % RH non-condensing at 50 °C
IP ratingIP67
Shock & VibrationVibration sweep sinus (EN 60068-2-6:2008) Vibration random (EN 60721-3-2: 1997 - Class 2M2) Shock (EN 60068-2-27:2009) MIL-STD-810D
Physical
Dimensions85.3 x 35 x 34 mm (incl. connectors)
Weight190 g
1) It depends on the devices connected, numbers of channels, configuration, length of cables and other parameters.

ECAT Power Injector technical specifications

EtherCAT POWER INJECTOR
Interface
Data interfaceEtherCAT®
Data Rate100 Mbps Full Duplex bus speed
Max. Throughput per ChainFrom 6 MB/s to 10 MB/s (see 1)
Sync Accuracy< 200 ns within same EtherCAT chain < 2 µs using sync for multiple EtherCAT chains below 1 sample to Sirius®
EtherCAT®Max. Cable Length 100 m
Max. Number of Units64 or more (power injectors may be required)
Data Interface ConnectionLEMO 1T EtherCAT® hybrid cable Single cable for data, power and sync, daisy chainable
Power specification
Power Supply9-48 V DC (see 2)
Environmental specification
Operating Temperature-40 to 85°C
Storage Temperature-40 to 85°C
IP ratingIP67
1) It depends on the devices connected, numbers of channels, configuration, length of cables and other parameters. 2) Passes through the EtherCAT signal, but cuts the power lines on the input.
Rev.: 1743064318 (27.3.2025)
Back to top