Inhaltsübersicht
Kategorien durchsuchen
Autoren durchsuchen
ALAlessia Longo
AHAl Hoge
BJBernard Jerman
BČBojan Čontala
CFCarsten Frederiksen
CSCarsten Stjernfelt
DCDaniel Colmenares
DFDino Florjančič
EBEmanuele Burgognoni
EKEva Kalšek
FBFranck Beranger
GRGabriele Ribichini
Glacier Chen
GSGrant Maloy Smith
HBHelmut Behmüller
IBIza Burnik
JOJaka Ogorevc
JRJake Rosenthal
JSJernej Sirk
JMJohn Miller
KMKarla Yera Morales
KDKayla Day
KSKonrad Schweiger
Leslie Wang
LSLoïc Siret
LJLuka Jerman
MBMarco Behmer
MRMarco Ribichini
MLMatic Lebar
MSMatjaž Strniša
MEMatthew Engquist
MEMichael Elmerick
NPNicolas Phan
OMOwen Maginity
PFPatrick Fu
PRPrimož Rome
RMRok Mesar
RSRupert Schwarz
SASamuele Ardizio
SKSimon Kodrič
SGSøren Linnet Gjelstrup
THThorsten Hartleb
TVTirin Varghese
UKUrban Kuhar
Valentino Pagliara
VSVid Selič
WKWill Kooiker
Neue DSI-Adapter für Typ-E-Thermoelemente und Strommessung

February 20, 2023
Wir freuen uns, die Markteinführung der neuen DSI-Adapter bekanntzugeben:
DSI-TH-E: Adapter für Typ-E-Thermoelemente für Temperaturmessungen
DSI-5A: überarbeiteter Strommessadapter für Ströme bis 5 A

Die vielseitigen DSI®-Adapter von Dewesoft wandeln alle in Dewesoft-Datenerfassungssystemen eingesetzten analogen Eingangsverstärker mit DSUB9-Stecker in universelle Analogeingänge um, die für alle Signalarten – von Dehnungsmessstreifen, IEPE/ICP, Thermoelementen, LVDT und RTD über Ströme bis hin zu Spannungen bis ±200 V – geeignet sind.
DSI-Adapter werden vom TEDS-Sensorchip (IEEE 1451.4) automatisch erkannt, und alle Einstellungen in der Datenerfassungsssoftware DewesoftX werden automatisch konfiguriert.
DSI-TH-E – Adapter für Typ-E-Thermoelemente für Temperaturmessungen
DSI-TH-E ist das neueste Modell in der Produktreihe der DSI®-Thermoelementadapter und für Thermoelemente vom Typ E vorgesehen.
Thermoelemente vom Typ E haben die höchste Empfindlichkeit (in mV/K) und sind für einen Temperaturbereich zwischen -270 °C und 1000 °C geeignet.
Die Konfigurations- und Kalibrierkoeffizienten des Host-Verstärkers können per TEDS eingelesen werden.
Host-Verstärker-Kompatibilität und -Spezifikationen
DSI-TH-E für Typ-E-Thermoelemente (DIN EN 60584-1)
| DAQ hardware | SIRIUS LVSIRIUS STGSIRIUS HD-STGS | SIRIUSi XHS-LVKRYPTONi STGIOLITE STG | SIRIUS STGMMINITAURs | DEWE-43ASIRIUSi HD-LV | SIRIUSi HS-LV | SIRIUSi HS-STG | SIRIUSi MULTI | |
| für Typ-E-Thermoelemente | Tatsächlicher Messwert | Grenzabweichung [max. Abweichung] | ||||||
| -270 bis 1000 °C | -250 bis -200 °C | ±2.3 [±10.2] °C | ±6.5 [±11.8] °C | ±3.2 [±10.2] °C | ±5.8 [±10.2] °C | ±1.7 [±11.8] °C | ±1.7 [±5.6] °C | ±3.2 [±19.0] °C |
| -200 bis -100 °C | ±1.5 [±5.0] °C | ±3.4 [±5.6] °C | ±1.9 [±5.0] °C | ±3.1 [±5.0] °C | ±1.3 [±5.6] °C | ±1.3 [±3.0] °C | ±1.9 [±8.7] °C | |
| -100 bis 0 °C | ±1.3 [±3.2] °C | ±2.3 [±3.6] °C | ±1.5 [±3.2] °C | ±2.1 [±3.2] °C | ±1.1 [±3.6] °C | ±1.1 [±2.1] °C | ±1.5 [±5.4] °C | |
| 0 bis 500 °C | ±1.3 [±2.4] °C | ±1.9 [±2.6] °C | ±1.4 [±2.4] °C | ±1.8 [±2.4] °C | ±1.2 [±2.6] °C | ±1.2 [±1.7] °C | ±1.4 [±3.7] °C | |
| 500 bis 1000 °C | ±1.6 [±2.8] °C | ±2.1 [±2.9] °C | ±1.8 [±2.8] °C | ±2.2 [±2.8] °C | ±1.4 [±2.9] °C | ±1.4 [±2.0] °C | ±1.8 [±4.2] °C |
DSI-5A - Strommessadapter
Außen unverändert, innen neu. Der DSI-5A v2 ist die neue Version des DSI®-Adapters für Strommessungen bis 5 A.
Der ursprünglich verwendete Shunt-Widerstand wird nicht mehr produziert - daher mussten wir uns nach einem Ersatz umsehen. Und wir fanden sogar einen viel besseren! Der DSI-5A v2 enthält einen 10-mΩ-Shunt mit einer Genauigkeit von 0,1 % (kalibriert). Eine signifikante Verbesserung gibt es bei der Temperaturstabilität. Der neue Shunt-Widerstand hat einen doppelt so guten Temperaturkoeffizienten wie bisher (15 ppm/K über den Bereich -55 °C bis 125 °C; vorher 30 ppm/K über den Bereich -20 °C bis 60 °C).
Als Eingangsanschluss ist der DSI-5A-Adapter mit der gewohnten 3-polige Schraubklemme für Leiter mit einem Nennquerschnitt bis 2,5 mm² ausgestattet.
Der Adapter wird über den eingebauten TEDS Chip erkannt und die Kalibrierkoeffizienten automatisch eingelesen.
DSI-5A Steckerbelegung
| Pin | Bezeichnung | Beschreibung |
|---|---|---|
| 1 | IN + | Strom-Eingang - |
| 2 | IN - | Strom-Eingang + |
| 3 | GND | Masse |
Weitere Informationen dazu: