电流传感器技术规格

DC-CT-1000I 电流传感器技术规格

DC-CT-1000I-S22DA
TypeZero-Flux
Primary Current Range DC (max)1000 A
Primary Current Range AC rms (max)700 A
Conversion ratio1:1680
DC Accuracy
Nominal Burden Resistance1 Ω (max. 3 Ω)
Transformer/Gain Off-Center Error10ppm (max. <30ppm)
Temperature influence (typ.)3 ppm/K
Nominal secondary current~595.2 mA @ 1000 A
Bandwidth ( -3 dB) (typ.)DC ... 500 kHz
Gain Linearity @1000 A rangeTyp. 83 ppm (max. <100ppm)
Offset including hysteresisTyp. 65 mA (max. 100 mA)
AC Accuracy
Frequency Bandwidth @ -0.5 dB, IP = 0.8 ARMS500 kHz
Frequency Bandwidth @ -3 dB, IP = 0.7 ARMS750 kHz
Noise (ppm rms)Min [mA]Typ [mA]Max [mA]
0 - 10000 Hz0.40.61.3
0 - 100000 Hz0.81.22
0 - 1000000 Hz5.45.56.5
Platiše Flux Sensor Frequency (seen as ripple)220 kHz
D-Class Switching Frequency (seen as ripple)750 kHz
Other
Time to Out of Range Detection (Status Deasserted)300 µs
Primary to Secondary Maximum Difference RTI±1500 mA
Status Open Collector Max CurrentTyp. 25 mA (Max. 50 mA)
Status Open Collector Max VoltageTyp. 60 V (Min. -5 V, Max. 80 V)
Immunity to external magnetic field, 5 mT in any direction RTITyp. ±30 mA (Max. < 50 mA)
Induced RMS voltage on primary conductor at IP = 032 µV
Induced RMS voltage on primary conductor during Search1223 µV
Power Supply
MinTypMax
Power Supply Voltage between pin 9 and 524 V30 V35 V
500 A Range Power Supply Voltage12 V30 V35 V
Power Supply Max. In-rush/working current @ 30 V< 0.5 A
Standby (Idle) Power ConsumptionTyp. 0.56 W (Max. 0.7 W)
Power Consumption @IP = 500 A and Burden 3 Ω3 W @IP = 500 A and Burden 3 Ω 6.6 W (max. 8 W) @IP = 1000 A and Burden 1 Ω 7.6 W (max. 9 W) @IP = 1000 A and Burden 3 Ω
Environmental
Operating temperature-40 °C to +85 °C
Non-insulated wire Isolation CAT II / CAT III IEC 61010-1 standards, EN 50178 standards1000 V CAT II 600 V CAT III
Insulated wire Isolation CAT II / CAT III IEC 61010-1 standards, EN 50178 standards1000 V CAT II 1000 V CAT III
Clearance / Creepage12 mm
Weight500 g
Inner diameter22 mm
Dimensions77 x 57 x 46.7 mm
DEWESoft® Shunt1 Ω
PWR-MCTS2 neededYes (±15 V)

磁通门交流/直流电流钳技术规格

DS-CLAMP-20DCDS-CLAMP-200DCDS-CLAMP-500DCSDS-CLAMP-500DCDS-CLAMP-1000DC
TypeFlux gateFlux gateFlux gateFlux gateFlux gate
Current Range20 A DC or AC RMS200 A DC or AC RMS500 A DC or AC RMS500 A DC or AC RMS1000 A DC or AC RMS
Sensitivity100 mV/A10 mV/A4 mV/A4 mV/A2 mV/A
BandwidthDC to 1 MHzDC to 500 kHzDC to 200 kHzDC to 100 kHzDC to 20 kHz
Bandwidth (upgraded after 2022)DC to 2 MHzDC to 700 kHzDC to 500 kHzDC to 200 kHzDC to 100 kHz
TEDSFully supportedFully supportedFully supportedFully supportedFully supported
Conductor Position Sensitivitymax. ± 0.1 % of readingmax. ± 0.1 % of readingmax. ± 0.1 % of readingmax. ± 0.2 % of readingmax. ± 0.2 % of reading
Zero Offset (+25°C)max. 10mAmax. ± 100 mAmax. ± 250 mAmax. ± 250 mAmax. ± 200 mA
Error due Earth Magnetic Fieldmax. ± 50 mAmax. ± 50 mAmax. ± 100 mAmax. ± 150 mAmax. ± 150 mA
Temp. Coefficient± 0.01 %/°C± 0.01 %/°C± 0.01 %/°C± 0.01 %/°C± 0.01 %/°C
Accuracy
FrequencyAmplitudePhase ErrorAmplitudePhase ErrorAmplitudePhase ErrorAmplitudePhase ErrorAmplitudePhase Error
DC± 0.2 % rdg. ± 10 mA-± 0.2 % rdg. ± 40 mA-± 0.3 % rdg. ± 100 mA-± 0.2 % rdg. ± 100 mA-± 0.2 % rdg. ± 200 mA-
to 100 Hz± 0.2 % rdg. ± 2 mA± 0.1 °± 0.2 % rdg. ± 20 mA± 0.1 °± 0.3 % rdg. ± 50 mA± 0.1 °± 0.2 % rdg. ± 50 mA± 0.1 °± 0.2 % rdg. ± 100 mA± 0.1 °
100 - 500 Hz± 0.3 % rdg. ± 4 mA± 0.2 °± 0.3 % rdg. ± 40 mA± 0.2 °± 0.3 % rdg. ± 100 mA± 0.2 °± 0.3 % rdg. ± 100 mA± 0.2 °± 0.5 % rdg. ± 200 mA± 0.2 °
500 Hz - 1 kHz± 0.5 % rdg. ± 4 mA± 0.5 °± 0.5 % rdg. ± 40 mA± 0.5 °± 0.5 % rdg. ± 100 mA± 0.5 °± 0.5 % rdg. ± 100 mA± 0.5 °± 1.0 % rdg. ± 200 mA± 0.5 °
1 kHz - 5 kHz± 1.0 % rdg. ± 4 mA± 1.0 °± 1.0 % rdg. ± 40 mA± 1.0 °± 1.0 % rdg. ± 100 mA± 1.0 °± 1.0 % rdg. ± 100 mA± (0.5 f [kHz]) °± 2.0 % rdg. ± 200 mA± (0.7 f [kHz]) °
5 kHz - 10 kHz± 1.5 % rdg. ± 4 mA± 1.5 °± 1.5 % rdg. ± 40 mA± 1.5 °± 1.5 % rdg. ± 100 mA± 1.5 °± 1.5 % rdg. ± 100 mA± (0.5 f [kHz]) °± 5.0 % rdg. ± 200 mA± (0.7 f [kHz]) °
10 kHz - 20 kHz± 2 % rdg. ± 4 mA± (0.5 + 0.1 f [kHz]) °± 5 % rdg. ± 40 mA± (0.5 + 0.1 f [kHz]) °± 5 % rdg. ± 100 mA± (0.15 f [kHz]) °± 5 % rdg. ± 100 mA± (0.5 f [kHz]) °± 30 % rdg. ± 200 mA± (0.7 f [kHz]) °
20 kHz - 50 kHz± 2 % rdg. ± 4 mA± (0.5 + 0.1 f [kHz]) °± 5 % rdg. ± 40 mA± (0.5 + 0.1 f [kHz]) °± 5 % rdg. ± 100 mA± (0.15 f [kHz]) °± 10 % rdg. ± 250 mA± (0.5 f [kHz]) °± 30 % rdg. ± 200 mA± (0.7 f [kHz]) °
50 kHz - 100 kHz± 5 % rdg. ± 10 mA± (0.5 + 0.1 f [kHz]) °± 10 % rdg. ± 100 mA± (0.5 + 0.1 f [kHz]) °± 15 % rdg. ± 250 mA± (0.15 f [kHz]) °± 30 % rdg. ± 250 mA± (0.5 f [kHz]) °--
100 kHz - 200 kHz± 10 % rdg. ± 10 mA± (0.5 + 0.1 f [kHz]) °± 15 % rdg. ± 40 mA± (0.5 + 0.1 f [kHz]) °± 30 % rdg. ± 250 mA± (0.15 f [kHz]) °----
200 kHz - 300 kHz± 10 % rdg. ± 10 mA± (0.5 + 0.1 f [kHz]) °± 15 % rdg. ± 40 mA± (0.5 + 0.1 f [kHz]) °± 30 % rdg. ± 250 mA± (0.15 f [kHz]) °----
300 kHz - 500 kHz± 15 % rdg. ± 10 mA± (0.5 + 0.1 f [kHz]) °± 30 % rdg. ± 100 mA± (0.5 + 0.1 f [kHz]) °------
500 kHz - 1 MHz± 30 % rdg. ± 10 mA± (0.5 + 0.1 f [kHz]) °--------
General Specifications
Dimensions [mm]153 x 67 x 25153 x 67 x 25153 x 67 x 25238 x 116 x 35238 x 116 x 35
Max. Conductor Size20 mm20 mm20 mm50 mm50 mm
Power Supply± 11 V to ± 15 V± 11 V to ± 15 V± 11 V to ± 15 V± 11.5 V to ± 15 V± 11.5 V to ± 15 V
Current Consumptionmax. 5 VAmax. 6 VAmax. 7 VAmax. 7 VAmax. 7 VA
Operating EnvironmentIndoors, Pollution Degree II, altitude up to 2000mIndoors, Pollution Degree II, altitude up to 2000mIndoors, Pollution Degree II, altitude up to 2000mIndoors, Pollution Degree II, altitude up to 2000mIndoors, Pollution Degree II, altitude up to 2000m
Operating Temp.- 40 °C to + 85 °C- 40 °C to + 85 °C- 40 °C to + 85 °C- 40 °C to + 85 °C- 40 °C to + 85 °C
Operating Humidityup to 80 % (not condensing)up to 80 % (not condensing)up to 80 % (not condensing)up to 80 % (not condensing)up to 80 % (not condensing)
Safety StandardsEN61010EN61010EN61010EN61010EN61010
EMC StandardsEN61326EN61326EN61326EN61326EN61326
Rohs-----
PWR-MCTS2 neededYesYesYesYesYes
Compatible amplifiers (see 1)SIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM, SIRIUS UNI IOLITE STG, IOLITE LVe KRYPTON STG DEWE 43SIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM, SIRIUS UNI IOLITE STG, IOLITE LVe KRYPTON STG DEWE 43SIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM, SIRIUS UNI IOLITE STG, IOLITE LVe KRYPTON STG DEWE 43SIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM, SIRIUS UNI IOLITE STG, IOLITE LVe KRYPTON STG DEWE 43SIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM, SIRIUS UNI IOLITE STG, IOLITE LVe KRYPTON STG DEWE 43
Cable length3 m - MCTS to Clamp 0.3 m - Amplifier to MCTS3 m - MCTS to Clamp 0.3 m - Amplifier to MCTS3 m - MCTS to Clamp 0.3 m - Amplifier to MCTS3 m - MCTS to Clamp 0.3 m - Amplifier to MCTS3 m - MCTS to Clamp 0.3 m - Amplifier to MCTS
Data SheetDS-CLAMP-20DCDS-CLAMP-200DCDS-CLAMP-500DCSDS-CLAMP-500DCDS-CLAMP-1000DC
1) The ranges of the IOLITE and KRYPTON amplifiers might affect the resolution of the measured values.

霍尔效应交流/直流电流钳技术规格

DS-CLAMP-30DCDS-CLAMP-150DCDS-CLAMP-150DCSDS-CLAMP-300DCDS-CLAMP-1800DC
TypeHall EffectHall EffectHall EffectHall EffectHall Effect
Current Range30 A DC or AC peak200 A DC or 150 A AC RMS250 A DC or 150 A AC RMS300 A DC or AC RMS1800 A DC or AC RMS
Sensitivity100 mV/A20 mV/A10 mV/A1 mV/A1 mV/A
Accuracy (+25°C)± 1 % of reading ± 2 mA1 % + 2 mA 1 % + 2 mA ± 1 % of reading ± 100 mA0 - 1000 A: ± 2.5 % of reading ± 0.5 A 1000 - 1500 A: ± 3.5 % of reading 1500 - 1800 A: ± 5 % of reading
BandwidthDC to 20 kHzDC to 100 kHzDC to 100 kHzDC to 20 kHzDC to 20 kHz
Resolution± 1 mA± 1 mA± 1 mA± 100 mA± 1 mA
TEDSFully supportedFully supportedFully supportedFully supportedFully supported
Conductor Position Sensitivity-± 0.5 %± 1 %± 1.5 % relative to center reading± 1.5 %
Zero Offset (+25°C)± 50 mV max.± 10 mV max. + 1 mV/°C± 10 mV max. + 0.1 mV/°C± 10 mV max.-
Error due Earth Magnetic Field-± 0.5 mV±0.5 mVmax. 1Amax. 150 mA
Temp. Coefficient± 0.01 % of reading / °C± 0.02 % of reading / °C± 0.02 % of reading / °C± 0.1 % of reading / °C± 0.15 % of reading / °C
ZeroExternal zero correctionAuto zero @ power supply of sensorAuto zero @ power supply of sensorExternal zero correctionAuto zero via push-button
General Specifications
Dimensions [mm]200 x 55 x 15205 x 60 x 15106 x 100 x 25192.60 x 55.30 x 15205 x 60 x 15
Max. Conductor Size32 mm32 mm25 mm25 mm32 mm
Power Supply + 12 V± 10 V± 10 V+ 12 V ± 3 V + 9 V
Current Consumption30 mA + 1 mA/A measured30 mA + 1mA/A measured30 mA + 1mA/A measuredmax. 30 mAmax. 25 mA
Jaws Open IndicationNoYesNoNoNo
Operating Temp.0 to + 50 °C0 to + 60 °C0 to + 60 °C0 to + 50 °C0 to + 50 °C
Operating Humidity-15 % to 85 % (not condensing)15 % to 85 % (not condensing)-15 % to 85 % (not condensing)
Safety StandardsEN 61010-1 EN 61010-2-032EN 61010-1:2010 EN 61010-2-032:2012 EN 61010-2-031:2012EN 61010-1:2010 EN 61010-2-032:2012 EN 61010-2-031:2012EN 61010-1 EN 61010-2-032EN 61010-1:2010 EN 61010-2-032:2012 EN 61010-2-031:2012
Safety300 Vrms CAT I300 Vrms CAT III300 Vrms CAT III300 Vrms CAT III300 Vrms CAT III
EMC StandardsEN 61326-2-2EN 61326-2-2:2013EN 61326-2-2:2013EN 61326-2-2EN 61326-2-2:2013
PWR-MCTS2 neededNoNoNoNoNo
Compatible AmplifiersSIRIUS LV / HS-LV / XHS-LV IOLITE LVe (see 1)SIRIUS LV / HS-LV (see 1)SIRIUS LV / HS-LV (see 1)SIRIUS LV / HS-LV / XHS-LV IOLITE LVe (see 1)SIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM, SIRIUS UNI IOLITE STG, KRYPTON STG IOLITE LVe DEWE-43
Cable length2 m3 m3 m3 m3 m
Data SheetDS-CLAMP-30DCDS-CLAMP-300DCDS-CLAMP-1800DC
1) *in-rush current is too high, so the clamps are not compatible with other amplifiers

交流电流夹技术规格

DS-CLAMP-5ACDS-CLAMP-15ACDS-CLAMP-200ACDS-CLAMP-1000AC
TypeIron-CoreIron-CoreIron-CoreIron-Core
Range5 A AC RMS15 A AC RMS200 A AC RMS1000 A AC RMS
Sensitivity100 mV/A100 mV/A10 mV/A1 mV/A
Accuracy (+25 °C)5 mA - 0.5 A ± 2 % of reading 0.5 A - 1 A ± 1 % of reading 1 A - 12 A ±0 .5 % of reading< 1 A ± 2.5 % of reading 1 A - 15 A ± 1 % of reading0.5 A - 10 A ± 3.5 % of reading 10 A - 100 A ± 2.5 % of reading 100 A - 240 A ± 1 % of reading< 1 A ± 2 % of reading 10 A - 100 A ± 0.5 % of reading 100 A - 1200 A ± 0.3 % of reading
Phase Error5 mA - 0.5 A ± 2 ° 0.5 A - 1 A ± 1° 1 A - 12 A ± 1 °< 1 A ± 5 ° 1 A - 15 A ± 3 °0.5 A - 10 A not specified 10 A - 100 A ≤ 5 ° 100 A - 240 A ≤ 2.5 °< 1 A not specified 10 A - 100 A ≤ 1 ° 100 A - 1200 A ≤ 0.7 °
Bandwidth2 Hz to 5 kHz2 Hz to 10 kHz2 Hz to 10 kHz2 Hz to 10 kHz
Resolution0.01 A0.01 A0.5 A0.001 A
TEDSFully supportedFully supportedFully supportedFully supported
Overload Capability1.5 x I nominal1.3 x I nominal1.3 x I nominal1.3 x I nominal
Conductor Position Sensitivity≤ 0.5 % of reading≤ 0.5 % of reading≤ 0.5 % of reading≤ 0.1 % of reading
Influence of Crest Factor≤ 1 %≤ 3 %≤ 3 %≤ 1 %
Error due Earth Magnetic Field/≤ 15 mV/A @ 50 Hz≤ 15 mV/A @ 50 Hz≤ 15 µV/A @ 50 Hz
Temperature Coefficient±0.015 % / °C≤ 0.2 % / 10 °C≤ 0.2 % / 10 °C≤ 0.1 % / 10 °C
Influence of Frequency/< 5 % of output signal from 20 Hz ... 1 kHz < 10 % of output signal from 1 kHz ... 10 kHz< 3 % of output signal from 20 Hz ... 1 kHz < 12 % of output signal from 1 kHz ... 10 kHz< 1 % of output signal from 30 Hz ... 48 Hz < 0.5 % of output signal from 35 Hz ... 1 kHz < 1 % of output signal from 1 kHz ... 5 kHz
General Specifications
Dimensions [mm]102 x 34 x 24135 x 51 x 30135 x 51 x 30216 x 111 x 45
Conductor Diameter15 mm20 mm20 mm52 mm
Operating Temperature-10 °C to +55 °C-40 °C to +70 °C-40 °C to +70 °C-40 °C to +70 °C
Operating Humidityup to 85 % (not condensing)up to 85 % (not condensing)up to 85 % (not condensing)up to 85 % (not condensing)
Safety StandardsEN61010-2 EN61010-2-032:2012EN61010-2 EN61010-2-032:2012EN61010-2 EN61010-2-032:2012EN61010-2 EN61010-2-032:2012
SafetyCAT III 600V CAT IV 300VCAT III 600V CAT IV 300VCAT III 600V CAT IV 300VCAT III 600V CAT IV 300V
EMC StandardsEN61326-1:2013EN61326-1:2013EN61326-1:2013EN61326-1:2013
PWR-MCTS2 neededNoNoNoNo
Compatible AmplifiersSIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM, SIRIUS UNI DEWE 43 IOLITE STG, KRYPTON STG IOLITE LVeSIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM, SIRIUS UNI DEWE 43 IOLITE STG, KRYPTON STG IOLITE LVeSIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM, SIRIUS UNI DEWE 43 IOLITE STG, KRYPTON STG IOLITE LVeSIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM, SIRIUS UNI DEWE 43 IOLITE STG, KRYPTON STG IOLITE LVe
Cable length2 m1.4 m1.4 m1.4 m
Data SheetDS-CLAMP-5ACDS-CLAMP-15ACDS-CLAMP-200ACDS-CLAMP-1000AC

零流量传感器技术规格

CT 100CT 200CT 400CT 500CT 1000CT 2000
TypeZero-FluxZero-FluxZero-FluxZero-FluxZero-Flux
Primary Current Range DC RMS Sinus100 A200 A400 A500 A1000 A2000 A
Conversion ratio1:5001:10001:15001:7501:15001:2000
Overload Ability Short Time (100 ms) 20 kApk20 kApk20 kApk5000 Apk5000 Apk10000 Apk
Max. measurement resistor (100 % of Ip)25 Ω20 Ω10 Ω5 Ω4 Ω3.5 Ω
Step response (0 ... 90%)0.2 μs0.2 μs1 μs1 μs1 μs1 μs
Temperature influence0.2 ppm/K0.2 ppm/K0.1 ppm/K1 ppm/K0.3 ppm/K< 0.1 ppm/k
Nominal secondary current200 mA at 100 A200 mA at 200 A266 mA at 400 A666 mA at 500 A666 mA at 1000 A1 A at 2000 A
Bandwidth ( -3 dB)DC ... 2 MHzDC ... 1.1 MHzDC ... 800 kHzDC ... 520 kHzDC ... 440 kHzDC ... 140 kHz
Linearity1.5 ppm1.2 ppm0.8 ppm3 ppm3 ppm3 ppm
Offset< 0.0015 %< 0.0010 %< 0.0008 %< 0.00115 %< 0.0012 %< 0.0012 %
Accuracy
FrequencyAmplitudePhase ErrorAmplitudePhase ErrorAmplitudePhase ErrorAmplitudePhase ErrorAmplitudePhase ErrorAmplitude ¹Phase Error ¹
DC0.002 %-0.001 %-0.0008 %-0.00115 %-0.0012 %-0.0012 %-
to 100 Hz0.015 %± 0.01 °0.015 %± 0.01 °0.015 %± 0.01 °0.015 %± 0.01 °0.015 %± 0.01 °0.015 %± 0.01 °
100 - 1 kHz0.025 %± 0.05 °0.02 %± 0.02 °0.02 %± 0.01 °0.02 %± 0.01 °0.02 %± 0.01 °0.05 %± 0.05 °
1 kHz - 10 kHz0.2 %± 0.1 °0.15 %± 0.05 °0.15 %± 0.1 °0.1 %± 0.05 °0.15 %± 0.1 °0.25 %± 0.1 °
10 kHz - 20 kHz0.5 %± 0.25 °0.5 %± 0.25 °0.5 %± 0.5 °0.2 %± 0.5 °1.5 %± 1 °1 %± 1 °
20 kHz - 50 kHz0.5 %± 0.25 °0.5 %± 0.25 °0.5 %± 0.5 °0.2 %± 0.5 °1.5 %± 1 °--
50 kHz - 100 kHz1 %± 0.5 °1 %± 0.5 °1 %± 1 °0.5 %± 1 °4 %± 2 °--
General Specifications
Rated isolation voltage RMS, single isolation CAT III, pollution deg. 2, IEC 61010-1 standards, EN 50178 standards 1000 V 1000 V 1000 V1000 V1000 V1000 V
Test voltage 50 / 60 Hz, 1 min4.95 kV4.95 kV4.95 kV4.2 kV4.2 kV6 kV
Inner diameter28 mm28 mm28 mm38 mm38 mm70 mm
Dimensions93 x 78.8 x 49.594 x 78.8 x 49.595 x 78.8 x 49.5128 x 106 x 54128 x 106 x 54231 x 220 x 76
Supply voltage (±5 %)±15 V±15 V±15 V±15 V±15 V±15 V
Operating humidity20 % to 80 % (not condensing)20 % to 80 % (not condensing)20 % to 80 % (not condensing)20 % to 80 % (not condensing)20 % to 80 % (not condensing)20 % to 80 % (not condensing)
Operating temperature- 40 °C to + 85 °C- 40 °C to + 85 °C- 40 °C to + 85 °C- 40 °C to + 85 °C- 40 °C to + 85 °C- 40 °C to + 85 °C
DEWESoft® Shunt5 Ω5 Ω5 Ω1 Ω1 Ω1 Ω
PWR-MCTS2 neededYesYesYesYesYesYes
Compatible amplifiers (see 1)SIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM, SIRIUS UNI DEWE 43 IOLITE STG, KRYPTON STG IOLITE LVeSIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM, SIRIUS UNI DEWE 43 IOLITE STG, KRYPTON STG IOLITE LVeSIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM, SIRIUS UNI DEWE 43 IOLITE STG, KRYPTON STG IOLITE LVeSIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM, SIRIUS UNI DEWE 43 IOLITE STG, KRYPTON STG IOLITE LVeSIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM, SIRIUS UNI DEWE 43 IOLITE STG, KRYPTON STG IOLITE LVeSIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM, SIRIUS UNI DEWE 43 IOLITE STG, KRYPTON STG IOLITE LVe
Cable length5 m - MCTS to Transducer 0.3 m - Amplifier to MCTS5 m - MCTS to Transducer 0.3 m - Amplifier to MCTS5 m - MCTS to Transducer 0.3 m - Amplifier to MCTS5 m - MCTS to Transducer 0.3 m - Amplifier to MCTS5 m - MCTS to Transducer 0.3 m - Amplifier to MCTS5 m - MCTS to Transducer 0.3 m - Amplifier to MCTS
Data Sheet
1) The ranges of the IOLITE and KRYPTON amplifiers might affect the resolution of the measured values.

AC Rogowsky盘管的技术规格

DS-FLEX-3000-17DS-FLEX-3000-35DS-FLEX-3000-35HSDS-FLEX-3000-80DS-FLEX-30000-120
TypeRogowski coilRogowski coilRogowski coilRogowski coilRogowski coil
Current Range3 A, 30 A, 300 A, 3000 A AC RMS3 A, 30 A, 300 A, 3000 A AC RMS3000 A AC RMS3 A, 30 A, 300 A, 3000 A AC RMS30 A, 300 A, 3000 A, 30000 A AC RMS
Sensitivity1000 mV/A, 100 mV/A, 10 mV/A, 1 mV/A1000 mV/A, 100 mV/A, 10 mV/A, 1 mV/A1 mV/A1000 mV/A, 100 mV/A, 10 mV/A, 1 mV/A100 mV/A, 10 mV/A, 1 mV/A, 0.1 mV/A
Accuracy (+25 °C)≤ 1.5 %≤ 1.5 %≤ 1.0 %≤ 1.5 %≤ 1.5 %
Phase Error @ 50 Hz≤ 1.0 deg≤ 1.0 deg≤ 1.0 deg≤ 1.0 deg≤ 1.0 deg
Bandwidth3 A: 10 Hz to 10 kHz Others: 10 Hz to 20 kHz3 A: 10 Hz to 10 kHz Others: 10 Hz to 20 kHz5 Hz - 1MHz3 A: 10 Hz to 10 kHz Others: 10 Hz to 20 kHz30 A: 10 Hz to 5 kHz Others: 10 Hz to 20 kHz
TEDSNot supportedNot supportedFully supportedNot supportedNot supported
Noise≤ 0.04 Arms≤ 0.04 Arms≤ 0.04 Arms≤ 0.04 Arms≤ 0.04 Arms
Temperature Coefficient≤ 0.5 % / 10 °C≤ 0.5 % / 10 °C≤ 0.5 % / 10 °C≤ 0.5 % / 10 °C≤ 0.5 % / 10 °C
General Specifications
Casing Dimensions [mm]120 x 58 x 36120 x 58 x 36140 x 64 x 28120 x 58 x 36120 x 58 x 36
Coil Length170 mm350 mm350 mm800 mm1200 mm
Coil Diameter45 mm100 mm100 mm250 mm380 mm
Power Supply+5 V+5 V+9 V+5 V+5 V
Operating Temperature- 10 °C to + 55 °C- 10 °C to + 55 °C- 10 °C to + 55 °C- 10 °C to + 55 °C- 10 °C to + 55 °C
Operating Humidityup to 90 % (not condensing)up to 90 % (not condensing)up to 90 % (not condensing)up to 90 % (not condensing)up to 90 % (not condensing)
Safety StandardsEN60529 EN61010-2 EN61010-2-032:2012EN60529 EN61010-2 EN61010-2-032:2012EN60529 EN61010-2 EN61010-2-032:2012EN60529 EN61010-2 EN61010-2-032:2012EN60529 EN61010-2 EN61010-2-032:2012
SafetyCAT IV 600VCAT IV 600VCAT III 1000VCAT IV 1000VCAT IV 1000V
EMC StandardsEN61326-1:2013EN61326-1:2013EN61326-1:2013EN61326-1:2013EN61326-1:2013
PWR-MCTS2 neededNoNoNoNoNo
Compatible amplifiersSIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM DEWE 43 IOLITE LVeSIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM DEWE 43 IOLITE LVeSIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG IOLITE STG, KRYPTON STG IOLITE LVeSIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM DEWE 43 *not tested yet with IOLITE and KRYPTON modulesSIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM DEWE 43 *not tested yet with IOLITE and KRYPTON modules
Cable length2.5 m (Extendable to 10 m upon request)2.5 m (Extendable to 10 m upon request)2.5 m (Extendable to 10 m upon request)2.5 m (Extendable to 10 m upon request)2.5 m (Extendable to 10 m upon request)
Data SheetDS-FLEX-3000-17DS-FLEX-3000-35DS-FLEX-3000-35HSDS-FLEX-3000-80DS-FLEX-30000-120
DS-FLEX-CWTUM6-1200A
TypeRogowski coil
Peak current1200 A
Sensitivity5 mV/A
Accuracymax. ± 2 % of reading
Linearity0.05 % of reading
DC offsetmax. ± 3 mV (@ 25°C)
Bandwidth3.2 Hz (-3 dB) ... 30 MHz (-3 dB)
Noisemax. 10 mVpp
TEDSSupported
di/dt70 kA/us (peak) 1.2 kA/us (rms)
General Specifications
Coil Length80 mm
Coil Cross Section1.7 mm
Operating Temperature- 40 °C to + 125 °C
Overvoltage protection1.2 kVpeak (rating established @ 3 kVrms, 50 Hz, 60 s flash test)
PWR-MCTS2 neededNo
Compatible amplifiersSIRIUS LV / HS-LV / XHS-LV SIRIUS STG / HS-STG SIRIUS STGM DEWE 43
Cable length1 m

MCTS电源装置的技术规格

SIRIUSi-PWR-MCTS2 / SIRIUSir-PWR-MCTSSIRIUSi-HD-PWR-MCTS2 / SIRIUSir-HD-PWR-MCTS
Power supply9 - 36 V DC9 - 36 V DC
Max power consumption85 W85 W
Physical dimensions265 x 140 x 65 mm265 x 140 x 65 mm
Operating temperature-20 °C to 50 °C-20 °C to 50 °C
Storage temperature-40 °C to 85 °C-40 °C to 85 °C
Humidity (@ 60 °C)95 % RH non-condensing95 % RH non-condensing
Output4 x Isolated Power supply (1500 V DC, 60 sec)8 x Isolated Power supply (1500 V DC, 60 sec)
Output voltage±15 V DC±15 V DC
Maximum output per channel20 W20 W
Short circuit protectionindefinite (automatic recovery)indefinite (automatic recovery)
Overload protection150 % of Iout max. typ150 % of Iout max. typ
回到顶部